(5) Data indication No. comparisons

The following table shows the comparisons of numbers for each symbols (Pr.,

Md., Cd., and Da.) indicating parameters or positioning data items.

The shaded sections indicate the added or changed items with the QD75.

Parameters

Item

A1SD75

QD75

Unit setting

Pr.1

No. of pulses per rotation (Ap)

Pr.2

Movement amount per rotation (Al)

Pr.3

Unit magnification (Am)

Pr.4

Pulse output mode

Pr.5

Rotation direction setting

Pr.6

Speed limit value

Pr.7

Pr.8

Acceleration time 0

Pr.8

Pr.9

Deceleration time 0

Pr.9

Pr.10

Bias speed at start

Pr.10

Pr.7

Stepping motor mode selection

Pr.11

Backlash compensation amount

Pr.12

Pr.11

Software stroke limit upper limit value

Pr.13

Pr.12

Software stroke limit lower limit value

Pr.14

Pr.13

Software stroke limit selection

Pr.15

Pr.14

Software stroke limit valid/invalid setting

Pr.16

Pr.15

Command in-position width

Pr.17

Pr.16

Torque limit setting value

Pr.18

Pr.17

M code ON signal output timing

Pr.19

Pr.18

Speed switching mode

Pr.20

Pr.19

Interpolation speed designation method

Pr.21

Pr.20

Current feed value during speed control

Pr.22

Pr.21

Manual pulse generator selection

Pr.23

Logic selection for pulse output to the drive unit

Pr.24

Input signal logic selection

Pr.22

Output signal logic selection

Pr.23

Manual pulse generator input selection

Pr.24

Size selection for acceleration/deceleration time

Pr.25

Acceleration time 1

Pr.26

Pr.25

Acceleration time 2

Pr.27

Pr.26