Melsec-q, 15 troubleshooting, 2] warnings – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual
Page 607
15 - 3
MELSEC-Q
15 TROUBLESHOOTING
Error storage
When an error occurs, the error detection input turns ON, and the error code
corresponding to the error details is stored in the following buffer memory address
(
Md.23
Axis error No.) for axis error No. storage. Note that there is a delay of up
to 1.8 ms after the error detection signal turns ON until the error code is stored.
Axis No.
Error detection signal
Buffer memory address
1
X8
806
2
X9
906
3
XA
1006
4
XB
1106
A new error code is stored in the buffer memory address (
Md.23
Axis error No.)
for axis error storage every time an error occurs.
[2] Warnings
Types of warnings
(1) Warnings include system warnings and axis warnings.
The types of system warnings are shown below.
•
System control data setting warnings
An axis warning for axis 1 will occur.
•
Positioning data setting warnings
An axis warning for each axis will occur.
Note that a warning will occur for the reference axis when an interpolation
designation or axis setting warning occurs.
(2) Axis warnings occur due to setting warnings from operations such as
positioning operations, JOG operations, manual pulse generator operations, or
system errors. They can be canceled by turning ON the " Cd.5 Axis error
reset".
Note that some warnings cannot be canceled unless the cause of the warning
is eliminated.
The axis operation status does not change even if an axis warning occurs.
(3) Types of warning codes
Warning code
Warning type
100 to 199
Common warning
300 to 399
Warning during JOG operation
400 to 499
Warning during manual pulse generator operation
500 to 599
Warning during positioning operation