Melsec-q, 9 major positioning control – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual
Page 394
9 - 94
MELSEC-Q
9 MAJOR POSITIONING CONTROL
Current feed value during speed-position switching control (ABS mode)
The following table shows the "
Md.20
Current feed value" during speed-position
switching control (ABS mode) corresponding to the "
Pr.21
Current feed value
during speed control" settings.
" Pr.21 Current feed value during
speed control" setting
Md.20 Current feed value
1: Update current feed value
The current feed value is updated during speed control
and position control.
Only "1: Update current value" is valid for the setting of "
Pr.21
Current feed value
during speed control" in speed-position switching control (ABS mode).
An error (error code: 935) will occur if the "
Pr.21
Current feed value during
speed control" setting is other than 1.
t
Speed
Position control
Speed control
Updated
Current feed value updated
Switching time from speed control to position control
There is 1ms from the time the speed-position switching signal is turned ON to the
time the speed-position switching latch flag (
Md.31
Status: b1) turns ON.
Speed-position switching signal
OFF
ON
OFF
ON
1ms
Speed-position switching latch flag