background image

5 - 113

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Storage buffer

memory address

Setting value

Default

value

Axis 1 Axis 2 Axis 3 Axis 4

Set with a decimal.

Setting
value

Positioning data No.

1 to 600
7000 to7004
9001
9002
9003
9004

K

: Positioning data No.
: Block start designation
: Machine OPR
: Fast-OPR
: Current value changing
: Simultaneous starting of multiple axes

0

1500

1600

1700

1800

Set with a decimal.

Setting
value

K

Positioning starting point No.

The value is set to "0" by the QD75 automatically when the continuous

operation is interrupted.

1 to 50

0

1501

1601

1701

1801

Set with a decimal.

K

1

Error reset request

Setting value

After the axis error reset is completed, "0" is stored by the QD75 automatically.
(Indicates that the axis error reset is completed.)

1: Axis error is reset.

0

1502

1602

1702

1802

Set with a decimal.

K

1

Restart command

Setting value

After restart acceptance is completed, "0" is stored by the QD75 automatically.
(Indicates that the restart acceptance is completed.)

1: Restarts

0

1503

1603

1703

1803

Set with a decimal.

K

1

M code OFF request

Setting value

After the M code ON signal turns OFF, "0" is stored by the QD75 automatically.
(Indicates that the OFF request is completed.)

1: M code ON signal turns OFF

0

1504

1604

1704

1804