beautypg.com

Melsec-q, 12 control sub functions – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 550

background image

12 - 74

MELSEC-Q

12 CONTROL SUB FUNCTIONS

End teaching?

Turn OFF the PLC READY
signal [Y0].

Carry out a writing request to
the flash ROM.

End

Confirm completion of writing.

Teaching arc end point address
on axis 2.

Entering teaching data to buffer memory address [1648] and [1649],
in the same fashion as for axis 1.

Set 1 in buffer memory address [1900].

Confirm 0 in buffer memory address [1900].

2)

1)

[Motion path]

OP

Reverse direction

Forward direction (Axis 1)

Arc center point

Movement by circular interpolation

(Axis 2)
Forward direction

*2 End point address

(arc address)

(positioning address)

Start point address

(current stop position)

Reverse direction

*1 Sub point address