beautypg.com

13 2-axis speed control, Melsec-q, Operation chart – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 370

background image

9 - 70

MELSEC-Q

9 MAJOR POSITIONING CONTROL

9.2.13 2-axis speed control

In "2-axis speed control" (" Da.2 Control system" = Forward run: speed 2, Reverse

run: speed 2), control is carried out in the 2-axis direction in which the positioning data

has been set by continuously outputting pulses for the speed set in " Da.8 Command

speed" until the input of a stop command.

The two types of 2-axis speed control are "Forward run: speed 2" in which the control

starts in the forward run direction, and "Reverse run: speed 2" in which control starts in

the reverse run direction.

(Refer to Section 9.1.6 "Interpolation control" for the combination of the reference axis

with the interpolation axis.)

Operation chart

The following chart shows the operation timing for 2-axis (axes 1 and 2) speed
control with axis 1 as the reference axis. The "in speed control" flag

(

Md.31

Status: b0) is turned ON during speed control.

The "positioning complete signal" is not turned ON.

t

V

BUSY signal
[XC,XD]

OFF

ON

Positioning start signal
[Y10]

OFF

ON

Positioning complete signal
[X14,X15]

OFF

Axis stop signal (stop command)
(Either Y4 or Y5)

OFF

ON

Does not turn ON even

when control is stopped

by stop command.

OFF

ON

Md.31

In speed control flag

Da. 8

Referense axis (axis1)

t

V

Command speed

Da. 8

Interpolation axis (axis 2)

Command speed

Status: b0

Fig. 9.10 2-axis speed control operation timing