beautypg.com

Melsec-q, 5 data used for positioning control – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 205

background image

5 - 117

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Storage buffer

memory address

Setting value

Default

value

Axis 1 Axis 2 Axis 3 Axis 4

0

1508
1509

1608
1609

1708
1709

1808
1809

Set with a decimal.

Cd.10 New acceleration time value

Cd.11 New deceleration time value

Setting

value

Example: When the " Cd. 10 New acceleration

time value" is set as "60000 ms", the

buffer memory stores "60000".

0

1510
1511

1610
1611

1710
1711

1810
1811

Set with a decimal.

Setting
value

K

Acceleration/deceleration time change

during speed change, enable/disable selection

1 : Enables modifications to

acceleration/deceleration time

Other than 1: Disables modifications to

acceleration/deceleration time

0

1512

1612

1712

1812