MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Setting value
Default value
Storage buffer
memory address
(common to axes 1
to 4)
Set with a decimal.
Setting
value
K
1
Flash ROM write request
1: Requests write access to flash ROM.
The QD75 resets the value to "0" automatically when the write access completes.
(This indicates the completion of write operation.)
0
1900
Set with a decimal.
Setting
value
K
Parameter initialization request
1: Requests parameter initialization.
The QD75 resets the value to "0" automatically when the initialization completes.
(This indicates the completion of parameter initialization.)
1
0
1901
Set with a decimal.
Setting
value
K
Deceleration start flag valid
0: Deceleration start flag invalid
1: Deceleration start flag valid
0
1905
Set with a decimal.
Setting
value
K
Stop command processing for deceleration stop selection
0: Deceleration curve re-processing
1: Deceleration curve continuation
0
1907