beautypg.com

Melsec-q, 5 data used for positioning control, Point – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 132

background image

5 - 44

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Pr.42 External command function selection

Select a command with which the external command signal should be associated.

0: External positioning start

The external command signal input is used to start a positioning
operation.

1: External speed change request

The external command signal input is used to change the speed
in the current positioning operation. The new speed should be set

in the "

Cd.14

Speed change value"

2: Speed-position, position-speed switching request

The external command signal input is used to switch from the
speed control to the position control while in the speed-position
switching control mode, or from the position control to the speed
control while in the position-speed switching control mode.
To enable the speed-position switching control, set the

"

Cd.24

Speed-position switching enable flag" to "1".

To enable the position-speed switching control, set the

"

Cd.26

Position-speed switching enable flag" to "1".

3: Skip request

The external command signal input is used skip the current
positioning operation.

POINT

To enable the external command signal, set the " Cd.8 External command enable"

to "1".