8 - 10

MELSEC-Q

8 OPR CONTROL

(3) If the "

Pr.49

OPR dwell time" elapses before the stop at the stopper, the workpiece

will stop at that position, and that position will be regarded as the OP.
At this time, an error will not occur.

Pr. 46 OPR speed

ON

ON

OFF

OFF

ON

0

V

ON

t

Pr. 47 Creep speed

Torque limit

Near-point dog OFF

Valid torque limit range

Dwell time measurement

Time out of dwell time

Machine OPR start
(Positioning start signal)

Deviation counter clear output

Md.26 Axis operation status

OPR request flag
[ Md.31 Status : b3]

OPR complete flag
[ Md.31 Status : b4]

Md.34 Movement amount
after near-point dog ON

Md.20 Current feed value

Md.21 Machine feed value

Standing by

In OPR

Inconsistent

Inconsistent

Value the machine moved is stored

Standing by

OP address

OFF

Stops at stopper

Pr.55 Deviation counter clear signal
output time

Fig. 8.6 Operation when the dwell time elapses before the stop at the stopper

(4) Machine OPR started while the near-point dog is ON will start at the "

Pr.47

Creep

speed".

(5) When a machine OPR is stopped with the stop signal, perform a machine OPR again.

If the restart command is turned ON after a stop with the stop signal, an error "OPR
restart not possible" (error code: 209) occurs.