12 CONTROL SUB FUNCTIONS

(2) Preparation

Prepare the absolute position detection system taking care of the following.

Component

Details

1) Servo amplifier

• Install the battery to the servo amplifier.

• Validate the absolute position detection function of the

servo amplifier.

Refer to the servo amplifier manual for details.

2) Servomotor

• Use a servomotor with absolute position detector.
Refer to the servomotor manual for details.

3) Detector cable

• Add a battery power connection cable (BAT/LG signal) for

wiring the incremental detector cable.

Refer to the cable operation manual for details.

4) PLC system

• Carry out the transmission and receiving of the absolute

position detection data by the I/O modules (input 3
points/output 3 points).

• Use the "16 point input module" and "16 point output

module".

[2] Outline of absolute position detection data communication

As shown in Fig. 12.33 System block diagram, the detector comprises an

encoder for detecting its position in one rotation in addition to the A, B, Z phase

signal for position control in normal operation and a cumulative rotation counter

for detecting the number of rotations.

The absolute position detection system detects the absolute position of the

machine constantly and stores it with the backup of the battery irrespective of

whether the PLC system power is turned ON/OFF. Thus, once the OP initial

setting is carried out at the time of installation of the machine, the OPR is not

required even when the power is later turned ON. The restoration can be carried

out easily when an instantaneous power interruption or emergency stop occurs.

In addition, because the absolute position data is backed up by a super

condenser built in the detector, the absolute position data will be stored for a

specified time even if the cable is disconnected or broken.

I/O module

PLC system

Current feed value

Current
position

change

QD75

QCPU

Output

Input

Servo amplifier

Position

control/
speed

control

Pulse train
command

OP data

Backup at

power OFF

LS0
1X0

1X
Detection of
position in one
rotation

LS

Speed

detection

Servomotor

Counter in one rotation

A.B.Z phase signal

Detector

1 pulse/rev cumulative rotation
counter

Super condenser

High-speed serial
communication

Battery

Current
position

Machine feed value

E PROM memory

2

Fig. 12.33 System block diagram