7 pinit, Melsec-q, Setting data – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual
Page 602: Control data
14 - 20
MELSEC-Q
14 DEDICATED INSTRUCTIONS
14.7 PINIT
This dedicated instruction is used to initialize the setting data of the QD75.
Usable device
Internal device
MELSECNET/10
direct J \
Constant
Setting
data
Bit
Word
File
register
Bit
Word
Special
module
U \G
Index
register
Zn
K, H, $
Others
(S)
–
–
–
–
(D)
–
–
–
–
[Instruction symbol]
[Execution condition]
PINIT
Z.PINIT
"Un"
(S)
(D)
[Setting data]
Setting data
Setting details
Setting side
( 1)
Data type
"Un"
QD75 head I/O number
(00 to FE: High-order two digits of I/O number expressed in three digits)
User
BIN 16 bits
(S)
Head number of a device in which control data is stored
–
Device
(D)
Head number of a bit device which turns ON the operation by one scan at the
time of completion of the instruction.
If the instruction is completed abnormally, ((D) + 1) will also be turned ON.
System
Bit
Note) The file register of each of the local device and the program cannot be used as a device for setting data.
[Control data]
Device
Item
Setting data
Setting range
Setting side
( 1)
(S)+0
System area
–
–
–
(S)+1
Complete status
The state at the time of completion is stored.
0
: Normal completion
Other than 0: Abnormal completion (error code)( 2)
–
System
1: The data on the setting side is as follows.
• User
: Data before the execution of dedicated instructions is stored by user.
• System: Data after the execution of dedicated instruction is stored by PLC CPU.
2: Refer to Section 15.2 for error codes at abnormal completion.