beautypg.com

Melsec-q, 5 data used for positioning control, Da.15 condition target – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 172: Da.16 condition operator, Da.17 address

background image

5 - 84

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Da.15 Condition target

Set the condition target as required for each control.

Setting value

Setting details

01

H

: Device X

02

H

: Device Y

Set the input/output signal ON/OFF as the conditions.

03

H

: Buffer memory (1-word)

04

H

: Buffer memory (2-word)

Set the value stored in the buffer memory as the condition.
03

H

: The target buffer memory is "1-word (16 bits)"

04

H

: The target buffer memory is "2-word (32 bits)"

05

H

: Positioning data No.

Select only for "simultaneous start".

Da.16 Condition operator

Set the condition operator as required for the "

Da.15

Condition target".

Da.15

Condition target

Setting value

Setting details

07

H

: DEV=ON

01

H

: Device X

02

H

: Device Y

08

H

: DEV=OFF

The state (ON/OFF) of an I/O signal is defined as the
condition. Select ON or OFF as the trigger.

01

H

:

∗∗

=P1

02

H

:

∗∗≠

P1

03

H

:

∗∗≤

P1

04

H

:

∗∗≥

P1

05

H

: P1

≤∗∗≤

P2

03

H

: Buffer memory (1-word)

04

H

: Buffer memory (2-word)

06

H

:

∗∗≤

P1, P2

≤∗∗

Select how to use the value (

∗∗

) in the buffer memory

as a part of the condition.

10

H

: Axis 1 selected

20

H

: Axis 2 selected

30

H

: Axes 1 and 2 selected

40

H

: Axis 3 selected

50

H

: Axes 1 and 3 selected

60

H

: Axes 2 and 3 selected

70

H

: Axes 1, 2, and 3 selected

80

H

: Axis 4 selected

90

H

: Axes 1 and 4 selected

A0

H

:Axes 2 and 4 selected

B0

H

: Axes 1, 2, and 4 selected

C0

H

: Axes 3 and 4 selected

D0

H

: Axes 1, 3, and 4 selected

05

H

: Positioning data No.

E0

H

:Axes 2, 3, and 4 selected

If "simultaneous start" is specified, select the axis
(or axes) that should start simultaneously.

Da.17 Address

Set the address as required for the "

Da.15

Condition target".

Da.15

Condition target

Setting value

Setting details

01

H

:

Device X

02

H

:

Device Y

Not used. (There is no need to set.)

03

H

:

Buffer memory (1-word)

04

H

:

Buffer memory (2-word)

Value

(Buffer memory address)

Set the target "buffer memory address".
(For 2 word, set the low-order buffer memory
address.)

05

H

:

Positioning data No.

Not used. (There is no need to set.)