5 - 34

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Pr.21 Current feed value during speed control

Specify whether you wish to enable or disable the update of "

Md.20

Current feed

value" while operations are performed under the speed control (including the
speed-position and position-speed switching control).
0: The update of the current feed value is disabled

The current feed value will not change.
(The value at the beginning of the speed control
will be kept.)

1: The update of the current feed value is enabled

The current feed value will be updated.
(The current feed value will change from the
initial.)

2: The current feed value is cleared to zero

The current feed will be set initially to zero and
change from zero while the speed control is in
effect.

Note1: When the speed control is performed over two to four axes, the choice

between enabling and disabling the update of "

Md.20

Current feed value"

depends on how the reference axis is set.

Note2: Set "1" to exercise speed-position switching control (ABS mode).

Pr.22 Input signal logic selection, Pr.23 Output signal logic selection

Set the I/O signal logic that matches the signaling specification of the connected
external device.
Note1: A mismatch in the signal logic will disable normal operation. Be careful of

this when you change from the default value.

Note2: Set the manual pulse generator input logic selection (b8) to axis 1. (Setting

of any of axes 2 to 4 is invalid.)

Pr.24 Manual pulse generator input selection

Set the manual pulse generator input pulse mode. (Only the value specified
against the axis 1 is valid.)

0: A-phase/B-phase; multiplied by 4
1: A-phase/B-phase; multiplied by 2
2: A-phase/B-phase; multiplied by 1
3: PULSE/SIGN

Pr.150

Speed-position function selection

Select the mode of speed-position switching control.

0: INC mode
2: ABS mode

Note1: If the setting is other than 0 and 2, operation is performed in the INC mode

with the setting regarded as 0.