Melsec-q, 5 data used for positioning control, Dc b a – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual
Page 178
5 - 90
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Storage item
Storage details
Reading the monitor value
Md.7
Error
judgment
[Storage details]
This area stores the following results of the error judgment performed
upon starting:
•
BUSY start warning flag
•
Error flag
•
Error No.
[Reading the monitor value]
Monitoring is carried out with a hexadecimal display.
b15
b12
b8
b4
b0
A
B
C
D
B
a
C
D
Buffer memory
Monitor value
D
C
B
A
Error flag OFF
Stored contents
Storage value
0
1
Error flag ON
Error flag
Error No.
Convert the hexadecimal value "a, B, C, D" into a decimal value and
match it with "15.2 List of errors".
BUSY start
warning OFF
Stored contents
Storage value
0
1
BUSY start
warning ON
BUSY start warning flag
Starting history
(U
p to 16 records can b
e
stored)
Md.8
Start history
pointer
Indicates a pointer No. that
is next to the Pointer No.
assigned to the latest of the
existing starting history
records.
Monitoring is carried out with a decimal display.
Monitor value
Storage value (Pointer number)
0 to 15