12 - 31

MELSEC-Q

12 CONTROL SUB FUNCTIONS

[7] Setting when the control unit is "degree"

Current value address

The "

Md.20

Current feed value" address is a ring address between 0 and

359.99999° .

359.99999°

359.99999°

Fig. 12.17 Current value address when the control unit is "degree".

Setting the software stroke limit

The upper limit value/lower limit value of the software stroke limit is a value
between 0 and 359.99999° .

(1) Setting when the software stroke limit is to be validated.

When the software stroke limit is to be validated, set the upper limit value in a
clockwise direction from the lower limit value.

Section A

315º

Set in a clockwise direction

Upper limit

Lower limit

90º

Section B

(a)

Set the movement range of section A as follows.

Software stroke limit lower limit value ................ 315.00000

°

.

Software stroke limit upper limit value................ 90.00000

°

.

(b)

Set the movement range of section B as follows.

Software stroke limit lower limit value ................ 90.00000

°

.

Software stroke limit upper limit value................ 315.00000

°

.

Fig. 12.18 Software stroke limit when the control unit is "degree"