9.1.5 Control unit "degree" handling

When the control unit is set to "degree", the following items differ from when other

control units are set.

[1] Current feed value and machine feed value addresses

The address of “

Md.20

Current feed value” becomes a ring address from 0 to

359.99999°.

But the address of “

Md.21

Machine feed value” doesn’t become a ring address.

359.99999°

359.99999°

[2] Software stroke limit valid/invalid setting

With the control unit set to "degree", the software stroke limit upper and lower

limit values are 0 to 359.99999.

(a) Setting to validate software stroke limit

To validate the software stroke limit, set the software stroke limit lower limit

value and the upper limit value in a clockwise direction.

Section A

Section B

315.00000

90.00000

Clockwise direction

0

1) To set the movement range A, set as follows.

• Software stroke limit lower limit value..................................315.00000º

• Software stroke limit upper limit value ...................................90.00000º

2) To set the movement range B, set as follows.

• Software stroke limit lower limit value....................................90.00000º

• Software stroke limit upper limit value .................................315.00000º

(b) Setting to invalidate software stroke limit

To invalidate the software stroke limit, set the software stroke limit lower

limit value equal to the software stroke limit upper limit value.

The control can be carried out irrespective of the setting of the software

stroke limit.