12 - 98

MELSEC-Q

12 CONTROL SUB FUNCTIONS

[3] Setting method

To use the "stop command processing for deceleration stop function", set the

following control data in a sequence program.

The set data are made valid as soon as they are written to the buffer memory.

The PLC ready signal [Y0] is irrelevant.

Setting item

Setting

value

Setting details

Buffer memory address

Cd.42

Stop command
processing for
deceleration stop
selection

Set the stop command processing for
deceleration stop function.

0: Deceleration curve re-processing

1: Deceleration curve continuation

1907

For details of the setting details, refer to "Section 5.7 Control data list".