9 MAJOR POSITIONING CONTROL

Setting the positioning data during interpolation control

When carrying out interpolation control, the same positioning data Nos. are set for
the "reference axis" and the "interpolation axis".
The following table shows the "positioning data" setting items for the reference
axis and interpolation axis.

Axis

Setting item

Reference axis setting item

Interpolation axis setting item

Da.1

Operation pattern

Da.2

Control system

Linear 2, 3, 4, Fixed-feed 2, 3, 4,
Circular sub, Circular right,
Circular left
Forward run speed 2, 3, 4
Reverse run speed 2, 3, 4

Da.3

Acceleration time No.

Da.4

Deceleration time No.

Da.5

Axis to be
interpolated.

Da.6

Positioning address/
movement amount

Forward run speed 2, 3, and 4.
Reverse run speed 2, 3, and 4 not
required.

Forward run speed 2, 3, and 4.
Reverse run speed 2, 3, and 4 not
required.

Da.7

Arc address

(Only during circular sub, circular
right, and circular left).

(Only during circular sub, circular
right, and circular left).

Da.8

Command speed

Only during forward run speed 2,

3, 4 and reverse run speed 2, 3, 4.

Da.9

Dwell time

Same positio

ning data N

o

s

Da.10

M code

: Setting always required
: Set according to requirements (Set to "–" when not used.)
: Setting restrictions exist

: Setting not required (Unrelated setting item, so any setting value will be ignored. Use the initial

value or a value within the setting range.)

: For 2-axis interpolation, the partner axis is set. If the self-axis is set, an error "Illegal interpolation

description command (error code: 521)" will occur. For 3- and 4-axis interpolation, the axis setting
is not required.

: Refer to Section 5.3 "List of positioning data" for information on the setting details.