Melsec-q, 9 major positioning control – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual
Page 381
9 - 81
MELSEC-Q
9 MAJOR POSITIONING CONTROL
Positioning data setting examples
The following table shows the setting examples when "4-axis speed control
(forward run: speed 4)" is set in the positioning data No. 1 of axis 1 (reference
axis).
Axis
Setting item
Axis 1
(reference
axis) setting
example
Axis 2
(interpolation
axis) setting
example
Axis 3
(interpolation
axis) setting
example
Axis 4
(interpolation
axis) setting
example
Setting details
Da.1 Operation pattern
Positioning
complete
–
–
–
Setting other than "Positioning
complete" is not possible in
speed control.
Da.2 Control system
Forward run
speed 4
–
–
–
Set 4-axis speed control.
Da.3
Acceleration time
No.
1
–
–
–
Designate the value set in
" Pr.25 Acceleration time 1"
as the acceleration time at start.
Da.4
Deceleration time
No.
0
–
–
–
Designate the value set in
" Pr.10 Deceleration time 0"
as the deceleration time at
deceleration.
Da.5
Axis to be
interpolated
–
–
–
–
Setting not required (setting
value will be ignored).
When axis 1 is used as a
reference axis, the interpolation
axes are axes 2, 3 and 4.
Da.6
Positioning address/
movement amount
–
–
–
–
Setting not required (setting
value will be ignored).
Da.7 Arc address
–
–
–
–
Setting not required (setting
value will be ignored).
Da.8 Command speed
6000.00
mm/min
3000.00
mm/min
2000.00
mm/min
1000.00
mm/min
Set the speed to be
commanded.
Da.9 Dwell time
–
–
–
–
Setting not required (setting
value will be ignored).
A
x
is 1 Positioning data N
o
. 1
Da.10 M code
10
–
–
–
Set this when other sub
operation commands are issued
in combination with the No. 1
positioning data. (" Pr.18 M
code ON signal output timing"
setting only possible in the
WITH mode.)
Refer to Section 5.3 "List of positioning data" for information on the setting details.