beautypg.com

Melsec-q, 9 major positioning control, Point – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 355

background image

9 - 55

MELSEC-Q

9 MAJOR POSITIONING CONTROL

Positioning data setting example

[Reference axis and interpolation axis are designated as axis 1 and axis 2,
respectively.]
The following table shows setting examples when "2-axis circular interpolation
control with sub point designation (ABS circular sub)" is set in positioning data No.
1 of axis 1. (The required values are also set in positioning data No. 1 of axis 2.)

Axis

Setting item

Axis 1

(reference

axis) setting

example

Axis 2

(interpolation

axis) setting

example

Setting details

Da.1 Operation pattern

Positioning

complete

Set "Positioning complete" assuming the next positioning
data will not be executed.

Da.2 Control system

ABS circular

sub

Set absolute system, 2-axis circular interpolation control with
sub point designation.

Da.3

Acceleration time
No.

1

Designate the value set in " Pr.25 Acceleration time 1" as

the acceleration time at start.

Da.4

Deceleration time
No.

0

Designate the value set in " Pr.10 Deceleration time 0" as

the deceleration time at deceleration.

Da.5

Axis to be
interpolated

1

Set the axis to be interpolated (partner axis).

If the self-axis is set, an error will occur.

Da.6

Positioning address/
movement amount

8000.0

µ

m

6000.0

µ

m

Set the positioning address. (Assuming "mm" is set in

"

Pr.1

Unit setting".)

Da.7 Arc address

4000.0

µ

m

3000.0

µ

m

Set the sub point address. (Assuming that the "

Pr.1

Unit

setting" is set to "mm".)

Da.8 Command speed

6000.00
mm/min

Set the speed when moving to the end point address.

(Designate the composite speed in " Pr.20 Interpolation

speed designation method".)

Da.9 Dwell time

500ms

Set the time the machine dwells after the positioning stop
(pulse output stop) to the output of the positioning complete
signal.

A

x

is 1 Positioning data N

o

. 1

Da.10 M code

10

Set this when other sub operation commands are issued in
combination with the No. 1 positioning data.

Refer to Section 5.3 "List of positioning data" for information on the setting details.

POINT

Set a value in " Da.8 Command speed" so that the speed of each axis does not

exceed the " Pr.8 Speed limit value". (The speed limit does not function for the

speed calculated by the QD75 during interpolation control.)