Melsec-q, 9 major positioning control, Point – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual
Page 355
9 - 55
MELSEC-Q
9 MAJOR POSITIONING CONTROL
Positioning data setting example
[Reference axis and interpolation axis are designated as axis 1 and axis 2,
respectively.]
The following table shows setting examples when "2-axis circular interpolation
control with sub point designation (ABS circular sub)" is set in positioning data No.
1 of axis 1. (The required values are also set in positioning data No. 1 of axis 2.)
Axis
Setting item
Axis 1
(reference
axis) setting
example
Axis 2
(interpolation
axis) setting
example
Setting details
Da.1 Operation pattern
Positioning
complete
–
Set "Positioning complete" assuming the next positioning
data will not be executed.
Da.2 Control system
ABS circular
sub
–
Set absolute system, 2-axis circular interpolation control with
sub point designation.
Da.3
Acceleration time
No.
1
–
Designate the value set in " Pr.25 Acceleration time 1" as
the acceleration time at start.
Da.4
Deceleration time
No.
0
–
Designate the value set in " Pr.10 Deceleration time 0" as
the deceleration time at deceleration.
Da.5
Axis to be
interpolated
1
–
Set the axis to be interpolated (partner axis).
If the self-axis is set, an error will occur.
Da.6
Positioning address/
movement amount
8000.0
µ
m
6000.0
µ
m
Set the positioning address. (Assuming "mm" is set in
"
Pr.1
Unit setting".)
Da.7 Arc address
4000.0
µ
m
3000.0
µ
m
Set the sub point address. (Assuming that the "
Pr.1
Unit
setting" is set to "mm".)
Da.8 Command speed
6000.00
mm/min
–
Set the speed when moving to the end point address.
(Designate the composite speed in " Pr.20 Interpolation
speed designation method".)
Da.9 Dwell time
500ms
–
Set the time the machine dwells after the positioning stop
(pulse output stop) to the output of the positioning complete
signal.
A
x
is 1 Positioning data N
o
. 1
Da.10 M code
10
–
Set this when other sub operation commands are issued in
combination with the No. 1 positioning data.
Refer to Section 5.3 "List of positioning data" for information on the setting details.
POINT
Set a value in " Da.8 Command speed" so that the speed of each axis does not
exceed the " Pr.8 Speed limit value". (The speed limit does not function for the
speed calculated by the QD75 during interpolation control.)