Appendix - 48

MELSEC-Q

APPENDICES

Functions deleted from those of A1SD75P1-S3/A1SD75P2-S3/A1SD75P3-S3

Deleted functions

Remarks

Stepping motor mode

OPR operation error (Error code: 208)

Fast machine OPR

Special start (stop)

Indirect designation

In the QD75, the start block area on the buffer memory is

expanded to five blocks (0 to 4). Each start block can be directly

designated with positioning start No. (7000 to 7004).

Block transfer

Positioning data I/F

With the A1SD75, this interface is used to set positioning data

Nos. 101 to 600 that do not exist on the buffer memory.

Since all positioning data can be set in the buffer memory with the

QD75, this function is deleted.

Start history storage during error

The contents are the same as those of the start history. Therefore,

the QD75 stores only the start history.

System monitor data (module type, OS information)

These data were deleted because they can be displayed in system

monitor "Module's detailed information" of GX Developer.

(Refer to GX Developer Operating Manual.)

Functions changed from those of A1SD75P1-S3/A1SD75P2-S3/A1SD75P3-S3

Changed functions

Descriptions

Software stroke limit function

1. The limit check of arc address is carried out only when a sub

point is designated. It is not carried out when a center point is

designated.

2. The software stroke limit check during speed control is carried

out in the following cases:

• When the software stroke limit is applied to the current feed

value with

Pr.14

and the current feed value is updated with

Pr.21

.

• When the software stroke limit is applied to the machine feed

value.

3. If an attempt is made to change the current value but the

designated address is out of the software stroke limit range, the

attempt is considered as an error and the current value is not

changed.

4. The conventional models feature three types of software stroke

limit error codes for upper limit and lower limit respectively. With

the QD75, errors for the software stroke upper limit are

integrated into error code 507, and errors for the lower limit are

integrated into error code 508. Error codes 509 to 512 are

deleted.

Current value changing

M code function

1. An error occurs when the designated new current value is out of

the software stroke limit range.

2. The M code setting value is valid during the positioning data

current value changing instruction.

Acceleration/deceleration control

1. An error occurs when the command frequency value calculated

from the speed limit value is out of the maximum command

frequency of the positioning module being used.

2. Only two-word type (1 to 8388608ms) can be used as the

setting value for the acceleration/deceleration time. (The switch

between 1-word type and 2-word type is eliminated.)