3 - 22
MELSEC-Q
3 SPECIFICATIONS AND FUNCTIONS
3.4.4 Input/output interface internal circuit
The outline diagrams of the internal circuits for the QD75P1/QD75D1 external device
connection interface are shown below.
(1) Input (Common to QD75P1 and QD75D1)
External wiring
Pin No.
Internal circuit
Signal name
Need for wiring
1
1A3
Near-point dog signal
DOG
1A1
Upper limit signal
FLS
1A2
Lower limit signal
RLS
1A4
Stop signal
STOP
1A5
External command
signal
CHG
1A6
1A7
Common
COM
(+)
1A19
PULSER A+
(–)
1B19
Manual pulse generator
A phase
PULSER A–
(+)
1A20
PULSER B+
(–)
1B20
Manual pulse generator
B phase
PULSER B–
1A11
Drive unit READY
READY
1A12
Drive unit READY
common
RDY COM
1A8
PG024
1A9
Zero signal
PG05
5VDC
5V
0V
A
B
Manual pulse
generator
(MR-HDP01)
When upper limit
switch is not used
When lower limit
switch is not used
24VDC
2
1A10
Zero signal common
PG0 COM
1: The symbols in Need for wiring column indicate the following meanings:
•
: Wiring is necessary for positioning.
•
: Wiring is necessary depending on the situation.
2: Either polarity can be connected to the common (COM).