beautypg.com

2 buffer memory area configuration, Melsec-q – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 269

background image

7 - 5

MELSEC-Q

7 MEMORY CONFIGURATION AND DATA PROCESS

7.1.2 Buffer memory area configuration

The QD75 buffer memory is configured of the following types of areas.

Buffer memory address

Buffer memory area configuration

Axis 1

Axis 2

Axis 3

Axis 4

Writing

possibility

Basic parameter area

0 to 15

150 to 165

300 to 315

450 to 465

Detailed parameter area

17 to 62

167 to 212

317 to 362

467 to 512

OPR basic parameter area

70 to 78

220 to 228

370 to 378

520 to 528

Parameter area

OPR detailed parameter

area

79 to 89

229 to 239

379 to 389

529 to 539

Possible

System monitor area

1200 to 1425

Monitor data area

Axis monitor area

800 to 847,

899

900 to 947,

999

1000 to

1047, 1099

1100 to

1147, 1199

Not possible

System control data area

1900, 1901, 1905, 1907

Control data area

Axis control data area

1500 to 1550 1600 to 1650 1700 to 1750 1800 to 1850

Possible

Positioning data area (No.1

to 600)

Positioning data area

2000 to 7999

8000 to

13999

14000 to

19999

20000 to

25999

26000 to

26049

27000 to

27049

28000 to

28049

29000 to

29049

Block start data area

26050 to

26099

27050 to

27099

28050 to

28099

29050 to

29099

Block start data area

(No.7000)

Condition data area

26100 to

26199

27100 to

27199

28100 to

28199

29100 to

29199

26200 to

26249

27200 to

27249

28200 to

28249

29200 to

29249

Block start data area

26250 to

26299

27250 to

27299

28250 to

28299

29250 to

29299

Block start data area

(No.7001)

Condition data area

26300 to

26399

27300 to

27399

28300 to

28399

29300 to

29399

26400 to

26449

27400 to

27449

28400 to

28449

29400 to

29449

Block start data area

26450 to

26499

27450 to

27499

28450 to

28499

29450 to

29499

Block start data area

(No.7002)

Condition data area

26500 to

26599

27500 to

27599

28500 to

28599

29500 to

29599

26600 to

26649

27600 to

27649

28600 to

28649

29600 to

29649

Block start data area

26650 to

26699

27650 to

27699

28650 to

28699

29650 to

29699

Block start data area

(No.7003)

Condition data area

26700 to

26799

27700 to

27799

28700 to

28799

29700 to

29799

26800 to

26849

27800 to

27849

28800 to

28849

29800 to

29849

Block start data area

26850 to

26899

27850 to

27899

28850 to

28899

29850 to

29899

Block start data area

(No.7004)

Condition data area

26900 to

26999

27900 to

27999

28900 to

28999

29900 to

29999

Possible

PLC CPU memo area

PLC CPU memo area

30000 to 30099

Possible

Use of address Nos. skipped above is prohibited. If used, the system may not operate correctly.