11 - 26

MELSEC-Q

11 MANUAL CONTROL

When "JOG start signal" is turned ON when peripheral devices are in the

test mode:

If "JOG star signal" is turned ON when peripheral devices are in the test mode, the
"JOG start signal" will be ignored and inching operation will not be carried out.

In test mode

ON

t

Forward run JOG start signal
[Y8,YA,YC,YE]

OFF

ON

OFF

Forward run inching
operation executed

Inching operation not possible

because the operation is in the

test mode.

Inching operation not

possible because JOG

start signal does not rise

Fig. 11.16 Operation when JOG start signal is turned ON in test mode

When "JOG start signal" is turned ON immediately after stop signal OFF

(within 100 ms):

If "JOG start signal" is turned ON immediately after the stop signal is turned OFF
(within 100 ms), the "JOG start signal" will be ignored and inching operation will
not be carried out.

Forward run JOG start signal
[Y8,YA,YC,YE]

ON

Axis stop signal
[Y4,Y5,Y6,Y7]

OFF

ON

OFF

Forward run inching operation

100ms

A rise of JOG start signal

is ignored.

Fig. 11.17 Operation when JOG start signal is turned ON immediately after stop signal is turned OFF