beautypg.com

Melsec-q, 15 troubleshooting – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 621

background image

15 - 17

MELSEC-Q

15 TROUBLESHOOTING

Related buffer memory

address

Axis 1 Axis 2 Axis 3 Axis 4

Set range

(Setting with sequence program)

Remedy

Correct the operation pattern.
(Refer to Section 5.3

Da.1

)

Same as error codes 515 to 516

Correct the control system.
(Refer to Section 5.3

Da.2

)

0

150

300

450

0, 1, 2, 3

Correct the positioning data or change the parameter
"Unit setting" of the axis to be interpolated.
(Refer to Section 9.1.6)

Same as error codes 515 to 516

• Correct the control system.

(Refer to Section 5.3

Da.2

)

• Correct the axis to be interpolated.

(Refer to Section 5.3

Da.5

)

Command speed storage

addresses of positioning

data No. 1 to 600

1 to 1000000 [pulse/s]

1 to 2000000000 [mm/min or others]

Correct the command speed.
(Refer to Section 5.3

Da.8

)

29

179

329

479

method>

0: Composite speed

1: Reference axis speed

Set the "Interpolation speed designation method"
correctly.
(Refer to Section 9.1.6)