beautypg.com

Melsec-q, 5 data used for positioning control, Da.7 arc address – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 156

background image

5 - 68

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Setting value, setting range

Setting value buffer memory

address

Item

Value set with peripheral device

Value set with sequence

program

Default

value

Axis 1 Axis 2 Axis 3 Axis 4

Da.7

Arc address

The setting value range differs according to the "

Da.2

Control

system".
Here, the value within the [Table 1] range is set.

[Table 1] on right page

0

2008
2009

8008
8009

14008
14009

20008
20009

Da.7 Arc address

The arc address is data required only when carrying out circular interpolation
control.
(1) When carrying out circular interpolation with sub point designation, set the sub

point (passing point) address as the arc address.

(2) When carrying out circular interpolation with center point designation, set the

center point address of the arc as the arc address.

End point address
(Address set with Da.6 )

Sub point
(Address set with Da.7 )

Start point address (Address before starting positioning)

Start point address (Address before starting positioning)

Center point address
(Address set with Da.7 )

End point address
(Address set with Da.6 )

<(1) Circular interpolation with sub

point designation>

<(2) Circular interpolation with center

point designation>

When not carrying out circular interpolation control, the value set in " Da.7 Arc

address" will be invalid.