9 - 32

MELSEC-Q

9 MAJOR POSITIONING CONTROL

Restrictions

An error will occur and the positioning will not start in the following cases. The
machine will immediately stop if the error is detected during a positioning
operation.

If the movement amount of each axis exceeds "1073741824 (=2

30

)" when "0:

Composite speed" is set in " Pr.20 Interpolation speed designation method"
... The "Outside linear movement amount range error (error code: 504)" occurs

at a positioning start.

(The maximum movement amount that can be set in " Da.6 Positioning

address/movement amount" is "1073741824 (=2

30

)".)

Positioning data setting example

[Reference axis and interpolation axis are designated as axis 1 and axis 2,
respectively.]
The following table shows setting examples when "2-axis linear interpolation
control (INC linear 2)" is set in positioning data No. 1 of axis 1. (The required
values are also set in positioning data No. 1 of axis 2.)

Axis

Setting item

Axis 1

(reference

axis) setting

example

Axis 2

(interpolation

axis) setting

example

Setting details

Da.1 Operation pattern

Positioning

complete

Set "Positioning complete" assuming the next positioning
data will not be executed.

Da.2 Control system

INC linear 2

Set incremental system 2-axis linear interpolation control.

Da.3

Acceleration time
No.

1

Designate the value set in " Pr.25 Acceleration time 1" as
the acceleration time at start.

Da.4

Deceleration time
No.

0

Designate the value set in " Pr.10 Deceleration time 0" as
the deceleration time at deceleration.

Da.5

Axis to be
interpolated

1

Set the axis to be interpolated (partner axis).

If the self-axis is set, an error will occur.

Da.6

Positioning address/
movement amount

9000.0

µ

m

-3000.0

µ

m

Set the movement amount. (Assuming "mm" is set in

"

Pr.1

Unit setting".)

Da.7 Arc address

Setting not required (setting value will be ignored).

Da.8 Command speed

6000.00
mm/min

Set the speed during movement.

Da.9 Dwell time

500ms

Set the time the machine dwells after the positioning stop
(pulse output stop) to the output of the positioning complete
signal.

A

x

is 1 Positioning data N

o

. 1

Da.10 M code

10

Set this when other sub operation commands are issued in
combination with the No. 1 positioning data.

Refer to Section 5.3 "List of positioning data" for information on the setting details.

POINT

When the "reference axis speed" is set during 2-axis linear intrpolation control, set

so the major axis side becomes the reference axis. If the minor axis side is set as

the reference axis, the major axis side speed may exceed the " Pr.8 Speed limit

value".