MELSEC-Q

10 HIGH-LEVEL POSITIONING CONTROL

10.4.2 Condition data setting examples

The following shows setting examples for "condition data".

(1) Setting the device ON/OFF as a condition

[Condition] Device "X0" (=QD75 READY) is OFF

Da.15

Condition target

Da.16

Condition

operator

Da.17

Address

Da.18

Parameter 1

Da.19

Parameter 2

01

H

: Device X

08

H

: DEV=OFF

0

(2) Setting the numeric value stored in the "buffer memory" as a

condition

[Condition]

The value stored in buffer memory addresses "800, 801" (= "

Md.20

Current

feed value") is "1000" or larger.

Da.15

Condition target

Da.16

Condition

operator

Da.17

Address

Da.18

Parameter 1

Da.19

Parameter 2

04

H

: Buffer memory

(2 words)

04

H

:

P1

800

1000

(3) Designating the axis and positioning data No. to be simultaneously

started in "simultaneous start"

[Condition]

Simultaneously starting "axis 2 positioning data No.3".

Da.15

Condition target

Da.16

Condition

operator

Da.17

Address

Da.18

Parameter 1

Da.19

Parameter 2

05

H

: Positioning

data No.

20

H

: Axis 2

designation

High-order 16

bits "0003

H

"