MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Da.10 M code (or condition data No./No. of LOOP to LEND repetitions)

Set an "M code", a "condition data No. ", or the "number of LOOP to LEND

repetitions" depending on how the " Da.2 Control system" is set.

If a method other than "JUMP instruction" and "LOOP" is selected as the

" Da.2 Control system"

............... Set an "M code".

If no "M code" needs to be output, set "0" (default value).

If "JUMP instruction" or "LOOP" is selected as the " Da.2 Control system"

............... Set the "condition data No." for JUMP.

0

: Unconditional JUMP to the positioning data specified

by Da.9 .

1 to 10 : JUMP performed according to the condition data No.

specified (a number between 1 and 10).

Make sure that you specify the number of LOOP to LEND repetitions
by a number other than "0". The "Control system LOOP setting error"
will occur if you specify "0". (error code: 545)

The condition data specifies the condition for the JUMP instruction to be

executed.

(A JUMP will take place when the condition is satisfied.)

[Table 1]

Pr.1

setting value

Value set with peripheral device

(unit)

Value set with sequence program

(unit)

0 : mm

0.01 to 20000000.00 (mm/min)

1 to 2000000000 (

×

10

-2

mm/min)

1 : inch

0.001 to 2000000.000 (inch/min)

1 to 2000000000 (

×

10

-3

inch/min)

2 : degree

0.001 to 2000000.000 (degree/min)

1 to 2000000000 (

×

10

-3

degree/min)

3 : pulse

1 to 1000000 (pulse/s)

1 to 1000000 (pulse/s)

[Table 2]

Da.2

setting value

Setting item

Value set with peripheral

device

Value set with sequence

program

JUMP instruction: 82

H

Positioning data No.

1 to 600

1 to 600

Other than JUMP instruction

Dwell time

0 to 65535 (ms)

0 to 65535 (ms)

[Table 3]

Da.2

setting value

Setting item

Value set with peripheral

device

Value set with sequence

program

JUMP instruction: 82

H

Condition data No.

0 to 10

0 to 10

Other than JUMP instruction

M code

0 to 65535

0 to 65535

LOOP: 83

H

Repetition count

1 to 65535

1 to 65535