MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Storage item

Storage details

Reading the monitor value

Md.3

Start
information

[Storage details]

This area stores the start information (restart flag, start origin, and start
axis):

Restart flag: Indicates whether the operation has or has not been

halted and restarted.

Start origin : Indicates the source of the start signal.

Start axis

: Indicates the started axis.

[Reading the monitor value]

Monitoring is carried out with a hexadecimal display.

Not used

0 0 0 0 0

b15

b12

b8

b4

b0

Buffer
memory

Monitor
value

PLC CPU

Stored contents

Storage value

00

01

10

External signal

Peripheral device

Start origin

Restart flag OFF

0

1

Restart flag ON

Restart flag

3

Axis 1

Axis 2

Axis 3

Axis 4

Start axis

1

2

4

Stored contents

Storage value

Stored contents

Storage value

Md.4

Start No.

The starting No. is stored.

Monitoring is carried out with a hexadecimal display.

Simultaneous start

2

3

2

C

9004

JOG operation

2

3

3

2

9010

Machine OPR

2

3

3

3

9011

Manual pulse generator

2

3

2

9

9001

Fast OPR

2

3

2

A

9002

Current value changing

2

3

2

B

9003

b15

b12

b8

b4

b0

A

B

C

D

B

A

C

D

Buffer
memory

Monitor value

D

C

B

A

Positioning operation

Stored contents

Storage value

Reference

(Decimal)

Start No.

A

0

0

0

to

B

C

D

1

001

1

B

5

8

0

2

5

8

7000

1

B

5

9

7001

1

B

5

A

7002

1

B

5

B

7003

1

B

5

C

7004

600

Md.5

Start

(Hour)

The starting time is stored.

Monitoring is carried out with a hexadecimal display.

Not used

0

b15

b12

0 0 0 0 0 0 0 0 0 0 1 0 1 0 1

b8

b4

b0

0

1

5

0

Buffer memory (stored with BCD code)

0

0

0 to 2

00 to 23 (hour)

0 to 3

Monitor value

0

0

1

5

Starting history

(U

p to 16 records can b

e

stored)

Md.6

Start

(Minute:
second)

The starting time is stored.

Monitoring is carried out with a hexadecimal display.

0 to 5

00 to 59 (second)

0

b15

b12

1 0 0 1 0 0 1 0 0 0 0 0 1 1 1

b8

b4

b0

9

0

7

4

Buffer memory (stored with BCD code)

0 to 5

0 to 9

00 to 59 (minute)

0 to 9

Monitor value

9

4

0

7

Note: If a start signal is issued against an operating axis, a record relating to this event may be output before a

record relating to an earlier start signal is output.