5 - 107

MELSEC-Q

5 DATA USED FOR POSITIONING CONTROL

Storage buffer

memory address

Reading the monitor value

Default

value

Axis 1 Axis 2 Axis 3 Axis 4

Monitoring is carried out with a decimal display.

00: Block start (Normal start)
01: Condition start
02: Wait start
03: Simultaneous start
04: FOR loop
05: FOR condition
06: NEXT

Storage value

Monitor
value

0

827

927

1027

1127

Monitoring is carried out with a decimal display.

Storage value

Monitor value

setting value

Md.36

00
06

01
02
03
05

04

1 to 10

0 to 255

Stored contents Storage value

None

None

Condition
data No.

No. of
repetitions

0

828

928

1028

1128

Monitoring is carried out with a decimal display.

Storage value
1 to 600

Monitor
value

0

829

929

1029

1129

Monitoring is carried out with a decimal display.

Storage value

Monitor
value

0: Not in speed limit (OFF)
1: In speed limit (ON)

0

830

930

1030

1130

Monitoring is carried out with a decimal display.

Storage value

Monitor
value

0: Not in speed change (OFF)
1: In speed change (ON)

0

831

931

1031

1131