Melsec-q, 15 troubleshooting – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual
Page 615
15 - 11
MELSEC-Q
15 TROUBLESHOOTING
Related buffer memory
address
Axis 1 Axis 2 Axis 3 Axis 4
Set range
(Setting with sequence program)
Remedy
Refer to Section 5.5
"List of condition data"
Axis designation:
10
H
, 20
H
, 30
H
, 40
H
, 50
H
,
60
H
, 70
H
, 80
H
, 90
H
, A0
H
,
B0
H
, C0
H
, D0
H
, E0
H
Normalize the condition operators.
(Refer to Section 5.5
Da.16
)
1540
1640
1740
1840 Axis 1 start data No.
1541
1641
1741
1841 Axis 2 start data No.
1542
1642
1742
1842 Axis 3 start data No.
1543
1643
1743
1843 Axis 4 start data No.
Simultaneous
start axis start
data No.
0 to 600
Normalize the simultaneous start axis start data No.
(Refer to Section 10.5)
1500
1600
1700
1800
1 to 600,
7000 to 7004,
9001 to 9004
1 to 600
Normalize the positioning start No., positioning start
data (in block start), and positioning data (in JUMP
instruction).
Refer to Section 5.3
"List of positioning data"
1 to 1000000 [pulse/s]
1 to 2000000000 [mm/min or others]
Normalize the positioning data.