beautypg.com

6 1-axis fixed-feed control, Melsec-q – MITSUBISHI ELECTRIC Mitsubishi Programmable Logic Controller QD75D User Manual

Page 343

background image

9 - 43

MELSEC-Q

9 MAJOR POSITIONING CONTROL

9.2.6 1-axis fixed-feed control

In "1-axis fixed-feed control" (" Da.2 Control system" = fixed-feed 1), one motor is

used to carry out fixed-feed control in a set axis direction.

In fixed-feed control, any remainder of the movement amount designated in the

positioning data is rounded down if less than that required for control accuracy to

output the same amount of pulses. (The remainder of the movement amount with an

accuracy below the control accuracy does not affect the regular controls.)

Operation chart

In 1-axis fixed-feed control, the address (

Md.20

Current feed value) of the current

stop position (start point address) is set to "0". Positioning is then carried out to a

position at the end of the movement amount set in " Da.6 Positioning

address/movement amount".
The movement direction is determined by the movement amount sign.

0

0

0

0

0

" Md. 20 Current feed
value" is set to "0" at
the positioning start

Designated movement

Positioning
start

amount

Reverse direction

Forward direction

Stop position

Movement direction for

a negative movement amount

Movement direction for

a positive movement amount

Restrictions

(1) An axis error "Continuous path control not possible (error code: 516)" will

occur and the operation cannot start if "continuous path control" is set in

" Da.1 Operation pattern". ("Continuous path control" cannot be set in fixed-

feed control.)

(2) "Fixed-feed" cannot be set in " Da.2 Control system" in the positioning data

when "continuous path control" has been set in " Da.1 Operation pattern" of

the immediately prior positioning data. (For example, if the operation pattern of
positioning data No. 1 is "continuous path control", fixed-feed control cannot
be set in positioning data No. 2.) An axis error "Continuous path control not
possible (error code: 516)" will occur and the machine will carry out a
deceleration stop if this type of setting is carried out.