Parameter descriptions – Enterasys Networks X-Pedition XSR CLI User Manual
Page 83
T1/E1 and T3/E3 Clear and Show Commands
XSR CLI Reference Guide 2-77
Latest II III IV
No Code No Code No Code No Code
Alarms Detected:
LOS LOF TxAIS RxAIS TxRAI RxRAI LOOP PayLd
X X X
24 Hour Statistics cleared: MAY 04 22:33:47
Current time: MAY 04 22:34:13
Interval LVC PCV CCV PES PSES SEFS UAS LES CES CSES
Total 4352 0 0 2 2 2 2 2 2 2
Current 4352 0 0 2 2 2 2 2 2 2
( 28s)
Note:
The 24 hour statistics is applied differently based on the selected farming type,
the following table marks the valid fields by a *
LCV PCV CCV PES PSES SEFS UAS LES CES CSES
T3 C_bit * * * * * * * * * *
T3 M13 * * - * * * * * - -
E3 G751 * SES * * *
E3 Bypass * *
Parameter Descriptions
Rx signal level ‐0.0DB
(Accuracy:+/‐3DB) [string]
String values can be:
•
NULL string: port locked on the signal; range 0 to 43.4
•
ʺnot validʺ: port could not lock on the signal 0 to 43.4
•
ʺhigh noise floorʺ: port locked on the signal, but signal is noisy 0 to 43.4.
This line determines if the port is connected to a valid T1/E1 signal. The port
will not function if the signal is ʺnot validʺ and will act unpredictable if it is
ʺhigh noise floorʺ. The line displays only if the Drop&Inset NIM is configured
for data and voice mode. If it is used in data mode, it will not display.
1 1 1 1 1 1 1 1 1 1 2 2 2 2 2
Time slot number TENs.
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
0 1 2 3 4
Time slot number units.