beautypg.com

Mode, Sample output – Enterasys Networks X-Pedition XSR CLI User Manual

Page 151

background image

Hardware Controller Clear and Show Commands

XSR CLI Reference Guide 4-99

Mode

Privileged EXEC or Global configuration: 

XSR#

or 

XSR(config)#

Sample Output

The following example displays output by the command:

XSR(config)#show interface bri 1/0

********** Serial Interface Stats **********
D-Serial 1/0:0 is Admin Up / Oper Down

********************** ISDN Stats ISDN-BRI 1/0 *********************
Layer 1: DOWN Layer 2: DOWN State: OFFLINE Admin Up Oper Down

Term. 1 Spid:2200555 State: OFFLINE Cause: 000
Term. 2 Spid:2201555 State: OFFLINE Cause: 000
Total Length = 257

The name of this device is bri0/1/0:0 .

The slot is 0.
The card is 1.
The port is 0.
The channel is 0.
The current MTU is 1500.
The device is in polling mode, and is active.
The channel is logically INACTIVE.
The operational state is OPER_DOWN.
The protocol used is LAPD.
The baud rate is 16000 bits/sec.
The device uses CRC-16 for Tx.
The device uses CRC-16 for Rx.

Other Interface Statistics:
ifindex 0
ifType 75
ifAdminStatus 1
ifOperStatus 2
ifLastChange 00:00:00
ifInOctets 0
ifInUcastPkts 0
ifInNUcastPkts 0
ifInDiscards 0
ifInErrors 0
ifInUnknownProtos 0
ifOutOctets 0
ifOutUcastPkts 0
ifOutNUcastPkts 0
ifOutDiscards 0
ifOutErrors 0
ifOutQLen 16

channel

ISDN BRI D‐ or B‐channel, either 0 for the D‐channel, and 1 or 2 for the B‐
channels.

sub-interface