Isdn disconnect – Enterasys Networks X-Pedition XSR CLI User Manual
Page 465
ISDN Commands
Book Title goes here 11-87
A PRI or BRI port can have only one ISDN calling‐number entry. For ISDN PRI, this command is
intended for use when the network offers better pricing on calls in which devices present the caller
number. When configured, the calling number is included in the outgoing setup message.
Syntax
isdn calling-number calling-number:subaddress
Syntax of the “no” Form
no isdn calling-number
Mode
BRI Interface configuration:
XSR(config-if
Example
The following example specifies a calling number for the XSR:
XSR(config)#interface bri 1/0
XSR(config-if
isdn disconnect
This command is used for debugging purposes to test ISDN connectivity. It sets up an ISDN data
call to test call setup procedures with a Central Office ISDN switch or test equipment. It is used to
disconnect a call before automatic disconnect occurs in 30 seconds or if a call is not dropped.
Syntax
isdn disconnect c/p channel_number
Mode
Privileged EXEC:
XSR#
Note: There is no mechanism to mark outgoing calls with the Calling Number and Calling
Subaddress for call routing on the receiving end.
calling-number
Number of the device making the outgoing call. Only one entry is
allowed.
:subaddress
Extension of the phone number.
Note: Enter this command in Privileged EXEC, not Global configuration mode.
c/p
BRI or PRI port ID.
channel_number
BRI: 1 or 2, E1 PRI: 0 to 31, T1 PRI: 0 to 22.