beautypg.com

Frame-relay lmi-t391dte – Enterasys Networks X-Pedition XSR CLI User Manual

Page 412

background image

Frame Relay Commands

9-88 Configuring Frame Relay

XSR(config)#interface serial 1/0
XSR(config-if)#no shutdown
XSR(config-if)#encapsulation frame-relay
XSR(config-if)#frame-relay intf-type dte
XSR(config-if)#frame-relay lmi-type ansi

The following example configures Serial interface 1/0 to act as a Frame Relay DCE, and to use the 
ANSI Annex‐D LMI:

XSR(config)#interface serial 1/0
XSR(config-if)#no shutdown
XSR(config-if)#encapsulation frame-relay
XSR(config-if)#frame-relay intf-type dce
XSR(config-if)#frame-relay lmi-type ansi

frame-relay lmi-t391dte

This command sets the interval between LMI Link Integrity Verification (LIV) message 
transmissions on the Data Terminal Equipment (DTE) interface.

Syntax

frame-relay lmi-t391dte period_in_sec

Syntax of the “no” Form

Use the no command to restore the default interval value:

no frame-relay lmi-t391dte

Default

10

Mode

Interface configuration: 

XSR(config-if<xx>)#

Example

Refer to the example in the

lmi-n391dte

command on

page 89

.

Note: On third-party devices, the LMI LIV period may be configured using the KeepAlive
configuration on the interface.

period_ in_sec

Sets the interval between LMI LIV polls, ranging from 5 to 330 seconds.