Pri-group – Enterasys Networks X-Pedition XSR CLI User Manual
Page 469
ISDN Commands
Book Title goes here 11-91
Examples
The following example configures two data streams on leased‐line BRI interface 1/1 at 56 kbps
with PPP encapsulation:
XSR(config)#interface bri 1/1
XSR(config-if
XSR(config)#interface bri 1/1:1
XSR(config-if
XSR(config-if
The following example configures BRI B‐channel 2:
XSR(config)#interface bri 1/1:2
XSR(config-if
XSR(config-if
The following example configures one data stream on leased‐line BRI interface 1/1 at 112 kbps
with Frame Relay encapsulation:
XSR(config)#interface bri 1/1
XSR(config-if
XSR(config)#interface bri 0/1/2:1
XSR(config-if
XSR(config-if
pri-group
This command configures a T1/E1 port to ISDN PRI on a channelized E1/T1 card. All 23 T1 or 30
E1 time slots are assigned to ISDN control.
Syntax
pri-group
Syntax of the “no” Form
The no form of this command deregisters the T1/E1 controller from the ISDN controller. Use the no
form to remove the ISDN PRI and restore the T1/E1 controller to its default mode:
no pri-group
Mode
Controller configuration:
XSR(config-controller
Example
The following NFAS example configures PRI with D‐channel backup:
XSR(config)#controller t1 1/0
XSR(config-controller