beautypg.com

Dsu mode – Enterasys Networks X-Pedition XSR CLI User Manual

Page 69

background image

T1/E1 & T3/E3 Commands

XSR CLI Reference Guide 2-63

XSR(config)#controller t1 1/0
XSR(config-controller)#framing esf
XSR(config-controller)#linecode b8zs
XSR(config-controller)#clock source line
XSR(config-controller)#description “Acme’s T1”

The following example describes the T3 controller in slot 1, card 2:

XSR(config)#controller t3 1/2
XSR(config-controller)#description “T3 Up at ACME”

dsu mode

For T3/E3 un-channelized controllers only

This command configures an unchannelized sub‐rate T3/E3 port to emulate a proprietary Data 
Service Unit (DSU) scheme. The XSR supports interoperability with a wide range of third‐party 
DSU vendors.

Local DSU mode configuration must match the remote configuration, so you must know what 
type of DSU is connected to the remote port to determine if it interoperates with a T3 or E3 NIM. 
This command enables interoperability with providers using various T3 or E3 DSUs to provision 
the T3/E3 line.

Syntax

dsu mode {digitallink | kentrox | larscom | adtran | verilink}

Syntax of the “no” Form

The no form of this command sets the DSU mode to the default value:

no dsu mode

Mode

Controller configuration:

XSR(config-controller xx)#

Example

The following example configures the T3 controller in slot 1, card 2 with line source clocking, M13 
framing, in unchannelized mode, with a cable length of 250 feet, and DSU interoperability mode 
set to an Adtran DSU:

XSR(config)#controllerXSR(config-controller)#no channelized
XSR(config-controller)#clock source line

digitallink

Digitallink mode connects the T3/E3 controller to a Digital Link, CISCO, 
or Quick Eagle DSU.

kentrox

Kentrox mode connects the T3/E3 controller to a Kentrox DSU.

larscom

Larscom mode links the T3 controller to a Larscom DSU.

adtran

Adtran mode connects the T3 controller to an Adtran T3SU 300.

verilink

Verilink mode connects the T3 controller to a Verilink HDM 2182.