beautypg.com

Table 6.12 output signal – serr, Output signal – serr, Table 6.12 – Avago Technologies LSI53C896 User Manual

Page 275

background image

DC Characteristics

6-7

Version 3.3

Copyright © 1998–2003 by LSI Logic Corporation. All rights reserved.

Table 6.11

Output Signals – INTA, INTB, ALT_INTA, ALT_INTB, REQ/

Symbol

Parameter

Min

Max

Unit

Test Conditions

V

OH

Output high voltage

0.9 V

DD

V

500

µ

A

V

OL

Output low voltage

0.1 V

DD

V

1500

µ

A

V

OH

5 V Tolerant output high voltage

2.4

V

16 mA

V

OL

5 V Tolerant output low voltage

0.55

V

16 mA

I

OZ

3-state leakage

10

10

µ

A

V

PIN

= 0 V, 5.25 V

I

PULL-UP

Pull-up current

1

75

7.5

µ

A

1. Pull-up test does not apply to REQ/.

Table 6.12

Output Signal – SERR/

Symbol

Parameter

Min

Max

Unit

Test Conditions

V

OL

Output low voltage

0.1 V

DD

V

1.5 mA

I

OZ

3-state leakage

10

10

µ

A