beautypg.com

Table 6.1 absolute maximum stress ratings, Table 6.2 operating conditions, Absolute maximum stress ratings – Avago Technologies LSI53C896 User Manual

Page 270: Operating conditions, Table 6.1

background image

6-2

Specifications

Version 3.3

Copyright © 1998–2003 by LSI Logic Corporation. All rights reserved.

Table 6.1

Absolute Maximum Stress Ratings

Symbol

Parameter

Min

Max

1

1. Stresses beyond those listed in this table may cause permanent damage to the device. These are

stress ratings only; functional operation of the device at these or any other conditions beyond those
indicated in the

Operating Conditions

section of the manual is not implied.

Unit

Test Conditions

T

STG

Storage temperature

55

150

°

C

V

DD

Supply voltage

0.5

4.5

V

V

IN

Input voltage

V

SS

0.3

V

DD

+0.3

V

V

IN5V

Input voltage (5 V tolerant pins)

V

SS

0.3

5.25

V

I

LP

2

2.

2 V < VPIN < 8 V.

Latch-up current

±

150

mA

ESD

3

3. SCSI pins only.

Electrostatic discharge

2 K

V

MIL-STD 883C,

Method 3015.7

Table 6.2

Operating Conditions

Symbol Parameter

Min

Max

1

1. Conditions that exceed the operating limits may cause the device to function incorrectly.
Core and analog supply only.

Unit

Test Conditions

V

DD

Supply voltage

3.13

3.47

V

I

DD

Supply current (dynamic)

2

200

mA

I

DD-I/O

LVD Mode Supply Current (dynamic)

600

mA

I

DD

Supply current (static)

1

mA

T

A

Operating free air

0

70

°

C

θ

JA

Thermal resistance (junction to ambient air)

20

°