Downloading Firmware for the MultiPro Unit

77

Required

Equipment for

Downloading

Software Requirements

DLL.EXE: This is the DOS program commonly used to download complete
software. It is needed the first time to download the core software present in the
MultiPro unit.

The NMCS program: This is the program that loads the task software to the
MultiPro unit Unit. The asynchronous port of the PC connects to a Poll/Select host
port of the unit.

*.INI: This DOS file contains all the information on the number of files to
download, their version number, their size, etc. This file is used by the NMCS.

*.HEX: These DOS files contain the task code to be downloaded.

Hardware Requirements

One PC running DOS and NMCS with a COM port available.

One RS-232 straight-through cable.

One TXPORT MultiPro unit. This unit must have a PSH (Poll/Select host) port
configured. If the unit is reset in config mode, a PSH port is already configured on
Port 3 at 38400 bps with address 00 and auto connect on unit 000. All the
parameters may be changed in the Configuration Menu of the MultiPro unit.

One Poll/Select Host port available on the local unit (The default is Port 3).

9101-, 9111-,

and 9211-Specific

Core Download

Procedure

This procedure applies only in cases where the MultiPro unit is not configured using
NMCS.

1

Connect the MultiPro unit’s Supervisory port to the serial port of the PC.

2

Apply power to the MultiPro unit.

3

Press and hold the Download button of the front of the MultiPro unit.

4

Press and release the reset button located on the rear panel of MultiPro unit.

5

Hold the Download button until all the front panel LEDs except Mode are on.

6

Release the Download button.

7

Type DLL and press Enter for command line options. An example command line:
DLL CORS608S.HEX 115. This command line specifies downloading core version
CORS608S.HEX at an 115-kbps baud rate.

8

The display shows:

Establishing connection. . .

Approximate transfer time = mm.mm

***********************************************************************************

*****************************