Configuration /operation, Level 1 and level 2 frame relay port parameters, Line module port description copy port parameters – Verilink 9000 Series (34-00271) Product Manual User Manual
Page 229: Configuration, Configuration / operation

Configuration / Operation
207
Configuration
/ Operation
Level 1 and Level 2
Frame Relay
Port Parameters
These parameters are described in the following paragraphs.
Defaults are shown underlined.
Line Module
This field indicates the line module number of the port currently being displayed.
Entering a different line module number and pressing F10 transfers the screen to
the same port on the new line module.
Port
The port field indicates the number of the port currently being displayed. A
different port may be selected by entering its number here and pressing F10.
Description
This is a free-form field intended to describe the location or department this port
services.
Copy Port Parameters
The three fields on this line work together to allow copying an existing port
configuration to the current port.
Configuration.
Enter the configuration number where the stations to be copied
reside.
TXPORT INTELLINET Configuration Program
Configuration 1000
Frame Relay Port Parameters - Level 1 and Level 2
Line Module [01] Port [2] Description [ ]
Copy Port Parameters from Configuration [ ] Module [ ] Port [ ]
Level 1 Level 2
Baud Rate [56000] Device (Network/FRAD) [F]
Interface (R/V) (9200 only) [R] N1 Counter (1 - 255) [ 10]
Termination (DCE/DTE) (9200 only) [DTE] N2 Counter (1 - 255) [ 5]
RTS/CTS Control (O/D/F) [0] N3 Counter (1 - 255) [ 5]
Active if DSR/DCD (B/S/N) [5] T1 Timer (sec) (1 - 255) [ 10]
T2 Timer (sec) (1 - 255) [ 15]
Recovery Counter (1 - 255) [ 3]
LMI Standard (CCITT/ANSI/TXPORT) [(]
ESC=Main Menu F1=Help F5=Clear F7=Redisplay F8=Jump F9=Previous F10=Next
Figure 12-2 Level 1 and Level 2 Frame Relay Transport Screen
✍