Configuration / Operation
87
Configuration
/ Operation
Unisys
Poll/Select
Terminal
Each of these parameters is described in the following paragraphs.
Defaults are shown underlined.
Line Module
This field indicates the line module number of the displayed port. Entering a
different line module number and pressing F10 transfers the screen to the same
port on the new line module.
Port
The port field indicates the number of the displayed port. A different port may be
selected by entering its number here and pressing F10.
Description
This is a free-form field intended to describe the location or department this port
services.
Copy Port Parameters
The three fields on this line work together to allow copying an existing port
configuration to the current port.
Configuration.
Enter the configuration number where the stations to be copied
reside.
TXPORT INTELLINET Configuration Program
Configuration 1 Unisys
Unisys Poll/Select Terminal Port Parameters
Line Module [01] Port [1] Description [Poll/Select Terminal ]
Copy Port Parameters from Configuration [ ] Module [ ] Port [ ]
Baud Rate [19200] Bits per Character (7/8) [7]
Parity (O/E/N) [E] Message Buffer [4096]
Interface (S/A/T/V) [T] Algorithm (S/C/G) [S]
Termination (DCE/DTE) (9200 only) [DCE] Contention Frequency (sec) [ 10]
Trailing Pads (0/1/2) [0] Consecutive Contention Polls [ 10]
Turnaround Delay (ms) [ 10] Timeouts to Mark Offline [ 3]
RTS/CTS Control (O/D/F) [F] Offline Delay Retry (sec) [ 30]
Drop DTR if DCD Drops (Y/N) [N] Maximum Selects before Poll [ 1]
Message Timeout (ms) [ 500] Select Retry Delay [ 10]
Active if DSR/DCD (B/S/N) [N] Downline Controller (Y/N) [N]
Poll & Select Timeout (ms) [ 300]
Activity Timeout (min) [ 0]
ESC=Main Menu F1=Help F5=Clear F7=Redisplay F8=Jump F9=Previous F10=Next