Menu

The Reset Function is normally used to reset the unit. The following menu is
displayed when this function is selected.

RESET MENU

---------------------

U - Unit reset

L - Line module reset

M - Main menu

Enter choice :

Choose either U to reset a unit or L to reset a specific line module. Both of theses
choices bring the following prompt.

ENTER TARGET ( unit.linemodule -> xxx.yy ) :

When selecting U, the line module must be 01.

Remote
Connection
Menu

The Remote Function is used to connect to or disconnect from a remote console.
When Remote Menu is selected from the main menu, the following screen is
displayed.

REMOTE CONNECTION MENU

L - List connections

C - Connect to remote unit

D - Disconnect from remote unit

M - Main menu

Enter choice:

List

connections

To display the list of connections, enter L. A screen similar to the following is
displayed.

CONNECTION SUMMARY

Active connection with unit # 000 (LOCAL)

Active connection with unit # 001 (REMOTE)

Active connection with unit # 002 (REMOTE)

Hit any key to continue

Remote

Console

Configuration

Tips

The console interface can initiate and configure remote units as though they were
locally connected. To do so reuires three things, first, every unit must have a
different unit number to allow remote connection. Second, an address on the link
between the local unit and the remote unit. For example, if the two units are linked
across an X.25 network, a logical channel for this connection is needed. In the
local unit, configure a logical channel with an unused address and the
corresponding subaddress. In the access list, define an access with the name
corresponding to the desired unit number, for example, 001. Remember to enter
the appropriate X.25 address. Third, make sure that the remote unit has the
corresponding logical channel on its X.25 port and its unit number is the one used
for the local access name. You are now ready to initiate a connection.