X.25 Layer 1 and Layer 2
225
X.25 Layer 1
and Layer 2
Defaults are shown underlined.
Line Module
This field indicates the line module number of the port being displayed. Entering a
different line module number and pressing F10 transfers the program to the same
port on the new line module.
Port
The port field indicates the number of the port being displayed. A different port
may be selected by entering its number here and pressing F10.
Description
This is a free-form field intended to describe the location or department this port
services.
Copy Port
Parameters
The three fields on this line work together to allow copying an existing port
configuration to the current port.
Configuration
Enter the configuration number where the stations to be copied reside.
Module
This parameter represents the line module number in the source unit.
Port
Enter the port number where the source stations reside.
TXPORT INTELLINET Configuration Program
Configuration 888 X.25 chapter
X.25 Port Parameters - Level 1 and Level 2
Line Module [01] Port [1] Description [X.25 Transport ]
Copy Port Parameters from Configuration [ ] Module [ ] Port [ ]
Level 1 Level 2
Baud Rate [56000] Logical Device (DCE/DTE) [DCE]
Interface (R/V) (9200 only) [R] Recovery Counter [ 3]
Termination (DCE/DTE) (9200 only) [XXX] Retransmission Busy Counter [ 10]
RTS/CTS Control (O/D/F) [O] Multilink (Y/N) [N]
Active if DSR/DCD (B/S/N) [S] Modulo (8/128) [ 8]
Window [ 7]
T1 Timer (sec) [ 3]
T2 Timer (sec) [ 1]
ESC=Main Menu F1=Help F5=Clear F7=Redisplay F8=Jump F9=Previous F10=Next
Figure 13-3 X.25 Port Parameters - Level 1 and Level 2 Screen
✍