Ncr terminal port parameters – Verilink 9000 Series (34-00271) Product Manual User Manual
Page 428

406
C
HAPTER
A: C
ONSOLE
I
NTERFACE
NCR Terminal
Port Parameters
(a) Link Speed: 300, 1200, 1800, 2400, 4800, 9600, 19200, or 38400 bps
(b) Character Length: 7 or 8 bits
(c) Parity: None, Even, or Odd
(d) Link Interface: Async, Sync, or TDI
(e) Link Termination: DCE or DTE
(f)
No Char before Tx: 1 to 4096
(g) Turnaround: 0 to 10 (in 10-millisecond increments), 1
(h) P/S Timeout: 1 to 65535 (in 10-millisecond increments), 100
(i)
Msg Timeout: 1 to 65535 (in 10-millisecond increments), 100
(j)
RTS/CTS Control: Dynamic, On, or Floating
(k) Drop DTR on DCD: Yes or No
(l)
Link Active: DSR & DCD, DSR Only, or Don’t Care
(m) Offline Count: 1 to 255 non-answered polls or selects, 3
(n) Offline Retry: 1 to 255 seconds, 30
(o) Select between Poll: 1 to 255 seconds, 2
(p) Select Retry Delay: 1 to 255 seconds, 10
(q) Activity Timer: 0 to 255 minutes
(r)
Address List
(a) Terminal Address: two displayable ASCII characters
(b) Terminal Name:
up to 17 ASCII characters except any three-numeral
hexadecimal digits (for example, 000 to FFF), null string. Also,
Terminal Names must be unique in a communications
platform.
(c) Default Address: two displayable ASCII characters
(d) Default Name: up to 17 ASCII characters, null string
(e) Poll Address: one ASCII character in the ranges 20
16
to 2F
16
(SP to /),
40
16
to 4F
16
(@ to 0), 60
16
to 6F
16
(‘ to o)
(f)
Device Type: 2262, 7900, 270, 796, ATM, or 279
(g) Options
Automatic Connection at Power On (Y or N) ?
Don’t Send Status Message (Y or N) ?
Reserved Channel (Y or N) ?
Sharable (Y or N) ?
Non-SMF Message Format (Y or N) ?
Non-NCR Host TA2 (Y or N) ?
Keep Message (Y or N) ?
Wait for Host Connection (Y or N) ?
Print Spooler (Y or N) ?
Defaults are underlined.