Frame Relay Protocol Parameters
411
Frame Relay
Protocol
Parameters
(a) Link Speed: 1200, 2400, 4800, 7200, 9600, 12000, 14400, 16800, 19200, 24000, 28800, 38400, 56000, or 64000 bps
(b) Link Interface: V.35 or RS-232
(c) Link Termination: DCE or DTE
(d) RTS/CTS Control: Dynamic, Fixed On, or Floating
(e) Link Active: DSR & DCD, DSR Only, or Don’t Care
(f) Type of Frame Relay Device: FRAD or Network
(g) Level 2 Parameters
(a) nN1: 1 to 255, 10
(b) nN2: 1 to 10, 5
(c) nN3: 1 to 10, 5
(d) nT1: 5 to 30 seconds, 10
(e) nT2: 5 to 30 seconds, 15
(f) LMI Standard: CCITT Q.933, ANSI T1.617, or TXPORT
(h) Level 3 Parameters
(a) Packet Size: 64, 128, 256, 512, 1024, Variable, Variable up to 1.8 kbytes, or 1 Message
(b) Restart Request Timer: 1 to 255 seconds, 15
(c) Call Request Timer: 1 to 255 seconds, 15
(d) Reset Request Timer: 1 to 255 seconds, 15
(e) Clear Request Timer: 1 to 255 seconds, 15
(f) Retry Counter: 1 to 255 seconds, 3
(g) VC Modulo: Modulo 8 or Modulo 128
(h) VC Window: 1 to 7 if Modulo 8 or 1 to 127 if Modulo 128, 7
(i) Number of VCs: 0 to 512, 64
(j) Postpone Timer: 0 to 512 seconds, 1
(k) Data Ack Timer: 0 to 512 seconds, 60
(i) Endpoint Identifier(This parameter is reserved for future use.)
(j) Endpoint List
(a) Endpoint Name: up to 17 ASCII characters, null string
(b) Alternate Name: up to 17 ASCII characters, null string
(c) DLC Identifier: 1 to 1022, null
(d) Clear
Defaults are underlined.