beautypg.com

Downloading the specific task software – Verilink 9000 Series (34-00271) Product Manual User Manual

Page 103

background image

Downloading Firmware for the MultiPro Unit

81

3

Press F10, to access the Line Module Parameters screen is displayed. Program the

listed parameters as follows.

Line Module Type:

9000

Firmware Version:

must match the firmware version on the Global
Parameters screen.

4

Press F10.

Downloading the Specific Task Software

Repeat this procedure for each line module.

1

Press Shift+F10 to access the Network Controller Software Upgrade Menu screen.

2

Configure the listed parameters as follows:

Configuration number:

(the same number as created in step 2)

Line Module:

1 to 3 in the 6400, 1 to 8 in the 6800

Upgrade File name:

_________. INI (The INI file must be in the same
subdirectory as ICP.EXE)

3

Press F10. The display shows:

Number of Tasks:01

Sending task: __________.HEX

BLOCK ___ OF ___ SENT

Press RETURN to continue

4

Wait until LED 1 starts blinking.

5

Set each 9000 card back to Run mode and the thumbwheels to 1, 2, 3, or 4.

6

Remove and apply power to the chassis.

7

Repeat this procedure for each 9000 card.